Need Help? +44 (0) 123 4567
You can add your content here.

AC-AC Transformer

Filters
Featured
Popularity
Date
Set Ascending Direction
View as Grid List
10 Items
24
36
48
60

An ac to ac transformer in this category covers three distinct jobs: isolated AC voltage measurement, current measurement, and AC regulation/dimming. Match the product family to the job before you compare specs. For mains-connected projects, isolation matters, and you cannot power a microcontroller directly from an AC-AC transformer because the output is still AC and still needs rectification and regulation.

24
36
48
60

Choose the right AC-AC product family first

Need Choose this family Example products on this page Why it fits Watch out for
Sense AC voltage safely in a measurement circuit Voltage transformer ZMPT101B precision voltage transformer, ZMPT107 high-accuracy voltage transformer A voltage transformer steps voltage for sensing and provides isolation. The ZMPT101B uses a 1000:1000 turns ratio with 4000V isolation, and the ZMPT107 also uses a 1000:1000 turns ratio with 4000V isolation and up to 2.5mA output. These are for isolated AC voltage monitoring, not for powering loads or microcontrollers directly.
Measure AC current in a wire or load Current transformer ZMCT103C 5A/5mA current transformer, ZMCT102W 5A/2.5mA current transformer, ZEMCT303A 40A/40mA current transformer A current transformer measures current through a magnetic core. The ZMCT103C is a 5A input/5mA output CT with a 1000:1 turns ratio, the ZMCT102W is 5A input/2.5mA output with a 2000:1 turns ratio and 4500V isolation voltage, and the ZEMCT303A provides a 40A/40mA range with ±1% accuracy for higher-current sampling. A CT does not step voltage down. It only measures current, so it is the wrong part if you need voltage conversion.
Dim a lamp, heater, or control motor speed SCR AC regulator/dimmer 2000W SCR AC-AC dimmer with external potentiometer, 5000W SCR dimmer with aluminum case These parts control AC power rather than measure it. The 2000W module provides 50V–220V AC adjustable output using a 25A bidirectional thyristor, while the 5000W regulator adjusts from 0V to input voltage for heavier AC control jobs. This family is for AC power control, not isolation and not sensing.
Power low-voltage DC electronics Neither of these families directly — No — you still need rectification and regulation after the transformer before powering a microcontroller. Measurement transformers and regulators feed sensing or control circuits, not DC loads. If your project ends at a controller, plan the bridge rectifier, regulator, and protection stage as well. For controller-based monitoring builds, these parts feed an Arduino board or similar ADC stage rather than the load itself.
Add isolation to a mains-facing measurement build Voltage transformer or higher-isolation current transformer ZMPT101B PCB-mount voltage transformer, ZMPT107 voltage monitoring transformer, ZMCT102W ultramicro CT These parts fit when the goal is isolated AC voltage monitoring or current sampling. Of the 5A CTs here, the ZMCT102W is the stronger isolation choice at 4500V. The isolation rating still needs to match the risk level of the installation.
Need adjustable AC output SCR regulator/dimmer, not a fixed ac power transformer 2000W SCR regulator dimmer, 5000W cased SCR voltage regulator Choose these when the job is light dimming, motor speed control, or trimming AC delivered to a load. Many variacs and other autotransformer-style variable transformers are not isolated, so adjustable AC is not the same as galvanic isolation.
Step voltage down with a current transformer Do not choose a CT — “A current transformer can be used as a voltage step-down” is a common beginner mistake, but the simpler and correct explanation is this: a CT only measures current. If you need isolated AC voltage measurement, choose a voltage transformer instead.

Sizing and safety checks before you buy an AC-AC transformer

  • Size any transformer by VA first: choose a transformer whose VA is at least voltage × current, plus a 20% safety margin.
  • For steady loads, a practical threshold is at least 1.2× expected load. If you want more headroom, use at least 1.5× load instead of matching the nameplate exactly.
  • For motors, compressors, and heating elements, allow 2–3× nameplate watts for startup surge headroom. That matters more than the steady-state number.
  • For low-power hobby mains sensing, 1kV isolation is the basic starting point. For industrial or higher-risk environments, look for at least 3kV isolation.
  • Frequency matters: a 50Hz-rated transformer on 60Hz is fine, but a 60Hz-only device on 50Hz can run into core saturation and overheating.
  • If you are checking compatibility with 120V / 60Hz mains, verify both the supported input voltage range and the frequency rating before you buy.
  • Use a fuse on the primary side. Absolutely protect against short-circuits and over-current instead of relying on the transformer or mains wiring to survive a fault.
  • For mains-connected current sensing, the ZMCT102W 5A/2.5mA CT stands out with 4500V isolation voltage, well above the 1kV hobby baseline.
  • Watch frequency limits on measurement parts: the ZMCT103C 5A/5mA precision CT is specified for 45-55 Hz, so it is not the right default choice for 60Hz work.
  • For AC control, load caveats matter as much as headline wattage. The 2000W SCR AC regulator is specifically recommended for voltage adjustment under 1000W or motor use under 3A in the intended setups.

Spec matrix: compare the measurement transformers and AC regulators

Product name Family Electrical rating Turns ratio or control range Isolation Accuracy or linearity Frequency Mounting or form factor Best-fit use
ZMPT101B 2mA/2mA precision voltage transformer Voltage transformer 2mA rated input/output 1000:1000 turns ratio 4000V isolation ≤0.2% linearity — PCB-mounted; requires PCB mounting with pin length greater than 3mm Isolated AC voltage measurement on a PCB
ZMPT107 2mA/2mA voltage transformer Voltage transformer 2mA primary/secondary current; 2.5mA max output 1000:1000 turns ratio 4000V isolation — — Epoxy encapsulation Isolated AC voltage monitoring where a compact encapsulated part fits
ZMCT103C 5A/5mA precision current transformer Current transformer 5A input / 5mA output 1000:1 turns ratio — 0.2 accuracy class 45-55 Hz Compact 18x24 mm body Compact current sampling where the line frequency matches
ZMCT102W 5A/2.5mA current transformer Current transformer 5A input / 2.5mA output 2000:1 turns ratio 4500V isolation voltage ≤ 0.2% linearity — Ultramicro form factor Precision 5A current sensing with higher isolation
ZEMCT303A 40A/40mA current transformer Current transformer 40A / 40mA rated current 1000:1 turns ratio — ±1% accuracy — Epoxy encapsulation; red and black output leads Higher-current motor sampling and overcurrent detection
2000W SCR AC-AC regulator dimmer SCR regulator/dimmer 2000W max power 50V–220V AC adjustable output — — — External potentiometer control with mounting nut Light dimming, motor speed control, temperature regulation
AC 220V 5000W SCR voltage regulator dimmer with case SCR regulator/dimmer 5000W power capacity 0V to input voltage adjustment range — — — Aluminum alloy case; SCR control Higher-power enclosed AC regulation

Common AC-AC transformer mistakes that change what you should buy

  • Choosing on price alone is a common mistake. A cheaper part with the wrong VA rating is more likely to overheat or underperform than a correctly sized one.
  • Physical fit does not prove electrical fit. Even if a step down transformer or sensing transformer fits the enclosure, the voltage, current, frequency, and isolation ratings still have to match the circuit.
  • Verify AC output vs DC output before checkout. Feeding AC into a DC device can damage it, and these products do not replace a regulated DC supply.
  • If you only need regulated 5V or 12V DC for a hobby build, a fixed-ratio AC-DC wall adapter is the more appropriate upstream choice than anything in this category.
  • Do not assume a variable transformer is safe isolation. Many variacs are autotransformers, so adjustable voltage does not equal shock protection.
  • A current transformer needs a burden resistor if you want a usable measurement voltage. Buying a CT without a burden resistor and ADC-scaling plan is a common reason sensing builds stall.
  • Yes, the ZMPT101B voltage transformer needs a burden resistor to set the correct input range for the downstream ADC, and direct compatibility with a 3.3V ADC is not implied without scaling.
  • Yes, the ZMCT102W 5A/2.5mA current transformer is suitable for measuring 5A motor current within its rating, but the burden resistor still has to match your ADC input range. For 3.3V measurement builds, that means pairing it with an ESP32 board or similar controller and designing the scaling stage accordingly.

FAQs on AC-AC Transformer

Do I need a transformer at all?

Check the device label for “100–240V 50/60Hz”; if it already accepts that range, you do not need a transformer, only a plug adapter. Buy from this category only when the device or circuit specifically needs AC output, sensing isolation, or adjustable AC.

Can I power a microcontroller directly from one of these?

No — an AC-AC transformer still outputs AC, so you need rectification and regulation before powering a microcontroller. In practice, that means adding a bridge rectifier and a regulated DC stage before the controller.

How do I choose the right size?

VA should be at least voltage × current, plus 20% safety margin; for motors or heaters, allow 2–3× startup headroom. That extra margin helps prevent voltage sag, nuisance heating, and overload during startup.

What is the difference between a current transformer and a voltage transformer?

A current transformer measures current through a magnetic core, while a voltage transformer is used to step voltage for sensing or isolation. Choose a CT for current sampling in a conductor and a VT for isolated AC voltage monitoring.

Are adjustable transformers isolated?

Not always — many variable transformers are autotransformers, so they do not provide galvanic isolation. If the install or bench setup needs shock separation from mains, treat adjustable output and isolation as two separate requirements.

Why does a small 12V AC transformer read high with no load?

A small 12V AC transformer can read about 16–18V with no load, and forum reports say 20–40% high unloaded is common. The voltage drops closer to its rated RMS value once the transformer is under its intended load.

Is humming or getting warm normal?

Some hum and operating heat are normal; 40–60°C is common, and loose laminations or mounting can cause buzz. What matters is whether the temperature and noise stay stable under the rated load rather than rising rapidly with normal use.

Glossary

VA (Volt-Ampere)
The apparent power rating that tells you how much voltage × current a transformer can handle safely.
Isolation Rating
The voltage the part can safely separate between sides, which is why it matters so much in mains-connected measurement projects.
Burden Resistor
A resistor used with a current transformer or voltage transformer to turn its output into a measurement voltage your ADC can read accurately.
Turns Ratio
The winding ratio, such as 1000:1 or 2000:1, that helps define how the transformer output relates to the input.
RMS
The AC value used for practical voltage and current sizing, rather than the higher peak value you might see on a scope.
Autotransformer
A transformer that shares windings between input and output, which is why many variable transformers do not provide full isolation.
To Top
Help
Shop
Account
0 Cart