| Sense AC voltage safely in a measurement circuit |
Voltage transformer |
ZMPT101B precision voltage transformer, ZMPT107 high-accuracy voltage transformer |
A voltage transformer steps voltage for sensing and provides isolation. The ZMPT101B uses a 1000:1000 turns ratio with 4000V isolation, and the ZMPT107 also uses a 1000:1000 turns ratio with 4000V isolation and up to 2.5mA output. |
These are for isolated AC voltage monitoring, not for powering loads or microcontrollers directly. |
| Measure AC current in a wire or load |
Current transformer |
ZMCT103C 5A/5mA current transformer, ZMCT102W 5A/2.5mA current transformer, ZEMCT303A 40A/40mA current transformer |
A current transformer measures current through a magnetic core. The ZMCT103C is a 5A input/5mA output CT with a 1000:1 turns ratio, the ZMCT102W is 5A input/2.5mA output with a 2000:1 turns ratio and 4500V isolation voltage, and the ZEMCT303A provides a 40A/40mA range with ±1% accuracy for higher-current sampling. |
A CT does not step voltage down. It only measures current, so it is the wrong part if you need voltage conversion. |
| Dim a lamp, heater, or control motor speed |
SCR AC regulator/dimmer |
2000W SCR AC-AC dimmer with external potentiometer, 5000W SCR dimmer with aluminum case |
These parts control AC power rather than measure it. The 2000W module provides 50V–220V AC adjustable output using a 25A bidirectional thyristor, while the 5000W regulator adjusts from 0V to input voltage for heavier AC control jobs. |
This family is for AC power control, not isolation and not sensing. |
| Power low-voltage DC electronics |
Neither of these families directly |
— |
No — you still need rectification and regulation after the transformer before powering a microcontroller. Measurement transformers and regulators feed sensing or control circuits, not DC loads. |
If your project ends at a controller, plan the bridge rectifier, regulator, and protection stage as well. For controller-based monitoring builds, these parts feed an Arduino board or similar ADC stage rather than the load itself. |
| Add isolation to a mains-facing measurement build |
Voltage transformer or higher-isolation current transformer |
ZMPT101B PCB-mount voltage transformer, ZMPT107 voltage monitoring transformer, ZMCT102W ultramicro CT |
These parts fit when the goal is isolated AC voltage monitoring or current sampling. Of the 5A CTs here, the ZMCT102W is the stronger isolation choice at 4500V. |
The isolation rating still needs to match the risk level of the installation. |
| Need adjustable AC output |
SCR regulator/dimmer, not a fixed ac power transformer |
2000W SCR regulator dimmer, 5000W cased SCR voltage regulator |
Choose these when the job is light dimming, motor speed control, or trimming AC delivered to a load. |
Many variacs and other autotransformer-style variable transformers are not isolated, so adjustable AC is not the same as galvanic isolation. |
| Step voltage down with a current transformer |
Do not choose a CT |
— |
“A current transformer can be used as a voltage step-down” is a common beginner mistake, but the simpler and correct explanation is this: a CT only measures current. |
If you need isolated AC voltage measurement, choose a voltage transformer instead. |